Power Systems - I Mid - II, April - 2012
1.Annual load factor is determined from _______ load curve
-
daily
-
monthly
-
annual
-
none of the above
-
Answer: C
2.The value of load factor is
-
always greater than 1
-
always less than 1
-
equal to 1
-
may be less than or greater than 1
-
Answer: B
3.The annual ________ cost is due to the annual cost of fuel, oil, taxation, wages &salaries to the operating staff
-
running
-
fixed
-
semi-fixed
-
none
-
Answer: A
4.Which of the following is not a type of power factor tariff?
-
KVA maximum demand tariff
-
KW & KVAR tariff
-
flat rate tariff
-
sliding scale tariff
-
Answer: C
5.The maximum value of power factor can be
-
1
-
0.5
-
0.9
-
0.3
-
Answer: A
6.Majority of distribution sub-stations are of _______ type
-
pole-mounted
-
indoor
-
outdoor
-
underground
-
Answer: A
7.Power factor correction substations are generally located at the ________ of transmission line
-
sending end
-
receiving end
-
midpoint
-
none of these
-
Answer: B
8.In an interconnected grid system, the diversity factor of the whole system ________
-
decreases
-
remains constant
-
increases
-
increases and then decreases
-
Answer: C
9.As the load factor approaches unity, the shape of load duration curve will be nearly
-
L shaped
-
inverted T shaped
-
triangular
-
rectangular.
-
Answer: D
10.In a 440 V system, in order to obtain the minimum cost and maximum benefits, the capacitor should be installed
-
at the load
-
near the transformer
-
any where in the circuit
-
near the earthling point.
-
Answer: A
11.The area under the daily load curve gives ________________.
Answer: units generated in the day
12.The value of demand factor is _________ than 1.
Answer: less
13.The maximum demand on a power station is 100 MW. If the annual load factor is 40% , the total energy generated in a year is _______________
Answer: 3504 * 10^5 KWH
14.The number of units generated will be more if the load factor is _________.
Answer: more
15.KVAR = ____________ tanф.
Answer: KW
16.The tariff in which power factor of the consumer’s load is taken into consideration is known as __________________.
Answer: power factor tariff
17.Most of the sub-stations in the power system change _______________ of electric supply.
Answer: voltage level
18.The possibility of fault escalation is _______ in outdoor substation than that of indoor substation.
Answer: less
19.The principle cause of voltage variation is the change of ________ on the system.
Answer: load
20.The p.f of an a.c circuit is given by __________ power divided by __________ power.
Answer: active , apparent