Biofluid Mechanics Mid - II, November - 2014
1.Rotameter is used to measure
-
Viscosity
-
Density
-
Flow meter
-
Pressure
-
Answer: C
2.More accurate flow measuring instrument is
-
Orifice meter
-
Venturi meter
-
Elbow meter
-
Flow meter
-
Answer: B
3.The range of coefficient discharge for orifice meter is
-
0.6-0.65
-
0.7 to 0.85
-
0.85-0.92
-
0.92 to 0.98
-
Answer: A
4.________________ is used to measure the flow through the pipe
-
Elbow meter
-
Manometer
-
Nozzle
-
Displacement pump
-
Answer: A
5.________________causes a fluid to move by trapping a fixed amount of it then forcing (displacing) that trapped volume into the discharge pipe.
-
A positive displacement pump
-
A negative displacement pump
-
Both
-
None
-
Answer: A
6.__________ is a type of positive displacement rotary pump.
-
Moving vane pump
-
Gear pump
-
Screw pump
-
All of the above
-
Answer: D
7.Reciprocating pumps includes _________
-
Plunger pumps
-
Diaphragm pumps
-
Both
-
None
-
Answer: C
8.The ______is a frictional force that acts parallel but opposite to the direction of motion
-
Reynolds’s number
-
Drag
-
Terminal velocity
-
None of the above
-
Answer: B
9.This flow measurement device is inserted directly into the pipeline to measure pressure
-
Orifice meter
-
Venturi meter
-
Manometer
-
Rotameter
-
Answer: B
10.Drag force ____________with increase in the free stream velocity.
-
Increases
-
Decreases
-
Remains constant
-
No relation
-
Answer: A
11.Hagen-Poisseuille equation describes steady flow through_______________
Answer: Rigid tubes.
12.When the fluid flows through an elbow higher pressure results at the _____________
Answer: outer wall
13.________________________are pumps that move fluid using the principles of rotation.
Answer: Positive displacement rotary pumps
14.In _____________pumps, the plunger pressurizes hydraulic oil which is used to flex a diaphragm in the pumping cylinder.
Answer: Diaphragm
15._____________________ is the common unit of power which is used to designate the power transformed to the fluid.
Answer: Hydraulic Horse power
16.The coefficient of the drag is the ratio between_______________ and ________________
Answer: Drag force and Dynamic force
17.____________ meters are not suitable for measuring pressures larger than 70kPa
Answer: Manometers
18.If the pressure drop is between 10% and 40% use of the midpoint properties will yield accurate _______________ losses.
Answer: Friction
19.A ________________ is a bent or a curved tube that carries fluid from a fluid surface at high elevation to fluid surface at low elevation.
Answer: Siphon
20.When a pipe with low friction factor is converted to an equivalent pipe with higher friction factor, the length ___________________
Answer: Decreases